Interlocking Nail Pins
Interlocking Nail Pins are designed to give surgeons the ability to combine the IMEX™ SK™ ESF device with the interlocking nail system by Innovative Animal Products. Utilizing these locking pins through the nail provides a significant increase in stability that can be especially useful in mechanically challenging fracture scenarios. In addition, locking pins allow for easy destabilization of the nail. The smaller, smooth portion is cut to length as determined by bone diameter. The larger diameter is gripped by the SK™ ESF clamp with the short, threaded area engaging the cis cortex. Three sizes are available:
| PART NO. | BOLT / PIN DIAMETER | NAIL DIAMETER | SK™ SIZE |
| 132025 | 2.0mm Bolt / 2.5mm Pin | 4.0mm or 4.7mm nails | Mini or Small SK™ |
| 132732 | 2.7mm Bolt / 3.2mm Pin | 6.0mm nails | Small or Large SK™ |
| 133540 | 3.5mm Bolt / 4.0mm Pin | 8.0mm nails | Small or Large SK™ |
TPLO Pins
These pins are designed for use as temporary osteotomy reduction pins during application of TPLO plates. Pins feature a long threaded length and a single trocar point with two diameters available. Implant quality 316LVM stainless steel.
| PART NO. | DIAMETER | THREADED LENGTH | OVERALL LENGTH |
| 29016 | 1.6mm | 45mm | 130mm |
| 29020 | 2.0mm | 65mm | 155mm |
Trans-ilial Rods and Nuts
Fully-threaded rods designed to provide additional
stability during the repair of unilateral or bilateral sacro-iliac luxations
and sacral fractures. Often used in addition to lag screws and can be combined
with other implants. Available in 3.2mm, 4.0mm, and 4.7mm diameters with
a single trocar point. Paired nuts can be applied to each end to provide
secure, locked fixation. Rods and nuts are implant quality, 316LVM stainless
steel.
| PART NO. | DIAMETER / LENGTH | ||
| 57032 | Trans-ilial Rod, 3.2mm x 125mm | ||
| 57040 | Trans-ilial Rod, 4.0mm x 155mm | ||
| 57047 | Trans-ilial Rod, 4.7mm x 175mm | ||
| --------- | ----------------------------------------------------------------- | ||
| 57132 | Trans-ilial Nut, 3.2mm (Requires 7mm Wrench) | ||
| 57140 | Trans-ilial Nut, 4.0mm (Requires 7mm Wrench) | ||
| 57147 | Trans-ilial Nut, 4.7mm (Requires 8mm Wrench) | ||
Multi-Purpose Orthopedic Washers
Originally designed for use with IMEX™ trans-ilial rods and nuts, multi-purpose orthopedic washers can also be used with standard bone screws. When using trans-ilial rods to augment repair of sacro-iliac luxations or pelvic fractures, these washers are designed for placement between the bone and trans-ilial nut to increase surface area; preventing compression into soft bone. Implant quality 316LVM stainless steel.
| PART NO. | WASHER SIZE | TRANS-ILIAL ROD DIA. | BONE SCREW SIZE |
| 57232 | 9mm | 3.2mm | 2.7mm |
| 57240 | 10mm | 4.0mm | 3.5mm |
| 57247 | 11mm | 4.7mm | 4.5mm |